Aisle-by-aisle occupancy control for storage, manufacturing and gyms

Most warehouse aisles sit empty most of the day, which makes them the biggest energy win in the building. Every solution below controls each aisle on its own: the lights sit low or off until a lift turns in, come up to full, and drop back when the aisle empties.
| Requirement | Typical code target | How the solutions meet it |
|---|---|---|
| Aisle control | Each aisle controlled independently of other aisles and open areas | One sensor group per aisle |
| Partial-off | Reduce lighting by at least 50% within 20 min of the aisle emptying | 0-10V dimming to the unoccupied level; time-out 20 min or less |
| Automatic shutoff | Building-wide off when unoccupied (schedule or sensor) | Sensors dim or turn off each aisle; add a schedule for after hours |
| Open areas | Separate control from aisles | Separate sensors over staging and dock areas |
Typical requirements of ASHRAE 90.1-2019 and the 2021 IECC. Local amendments and other code editions differ; the adopted code for the project governs.
DANLERS ISI-HBWD wide-detection sensors mount over the aisle centerline and dim that aisle's fixtures over 0-10V. Racking blocks the view, so each sensor sees only its own aisle.
| Qty | Model | Description |
|---|---|---|
| 9 | ISI-HBWD10V12V | High bay sensor, 0-10V, three per aisle |
| — | 12 V DC Class 2 supply | Sensor power per wiring guide |
| — | 0-10V control wiring | One group per aisle |
Tech sheet: ES-TS-104
ILLUMRA E9T-OSH self-powered high bay sensors link to an E9X-DUV-10VTP dimming controller for each aisle's circuit, so no low-voltage wiring runs across the racks.
| Qty | Model | Description |
|---|---|---|
| 6 | E9T-OSH | Self-powered high bay occupancy sensor, two per aisle |
| 3 | E9X-DUV-10VTP | 20 A 0-10V dimming controller, one per aisle |
Tech sheet: ES-TS-105 / 107
An ISI MOD17M module in each high bay fixture controls that fixture, so the lit area follows the lift down the aisle. See ES-DG-06 for fixture-integrated design.
| Qty | Model | Description |
|---|---|---|
| 15 | ISI-MOD17M10V12V | Luminaire sensor module, one per fixture |
| 15 | 12 V DC supply | ISI-PSU12VDC or driver auxiliary supply |
Tech sheet: ES-TS-104
ES-TS-104 ISI smart sensors · ES-TS-105 Self-powered wireless sensors · ES-TS-107 Wireless load controllers
Download this guide as a PDF. Other guides: Private offices · Open offices & classrooms · Restrooms & stalled spaces · Hotels & dorms · Fixture-integrated sensing
Starting points only: check every project against its adopted energy code, the reflected ceiling plan and current manufacturer data. Diagrams are illustrative. Send plans to info@energiocontrols.com for a project layout. Products by B.E.G., DANLERS and ILLUMRA. Photo: Unsplash License.