Fixture-integrated sensing

Sensors built into the luminaire, in the field or at the factory

Design guide
Fixture-integrated sensing
Photo: Tsuyoshi Kozu / Unsplash

Putting the sensor in the fixture takes it off the ceiling plan: every luminaire controls itself, coverage grows with the fixture layout, and there is no separate device to locate or wire. All three solutions suit private-label Energio Lighting fixtures built with sensing at the factory.

Design goals

Solutions in this guide

Code checklist

RequirementTypical code targetHow the solutions meet it
Shutoff / partial-offOff or reduced within 20 min of vacancyEach fixture's sensor time-out 20 min or less
Control zonesZone size limits in open areasOne fixture or small group per zone is inherently within limits
Daylight-responsive controlDimming in sidelighted and toplighted zonesSensor photocell dims each fixture to the daylight
Restricted auto-onManual-on or auto-on to no more than 50% where requiredSet the occupied level, or add a manual switch

Typical requirements of ASHRAE 90.1-2019 and the 2021 IECC. Local amendments and other code editions differ; the adopted code for the project governs.

A

Solution A: Smart sensor module in each fixture

App-configured · 0-10V or DALI
  • Fixture with sensor module
  • Windows

A DANLERS ISI MOD17M module in each luminaire dims or switches that fixture from presence and daylight. Settings are made from the ISI app.

  • One module per fixture, mounted where the optic doesn't shade the lens
  • Wire modules with the same output in parallel to group fixtures
  • 12 V DC from ISI-PSU12VDC or the driver's auxiliary supply
QtyModelDescription
12ISI-MOD17M10V12VLuminaire sensor module, 0-10V
1212 V DC supplyISI-PSU12VDC or driver auxiliary

Tech sheet: ES-TS-104

B

Solution B: MINI sensor and power pack in the fixture

Low voltage · OEM bracket
Row 1Row 2Row 3PPP
  • Fixture with sensor module
  • PPrimary MINI + power pack
  • Control zone

A MINI primary and power pack mount in or on the luminaire with B.E.G.'s OEM bracket; secondary MINIs in neighboring fixtures extend one zone across a row.

  • One primary + PP-DIM-J per row or zone
  • Secondary MINIs in the other fixtures of the row
  • IP65 MINI suits wet and high-humidity fixtures
QtyModelDescription
3MINI-P-PP-DIM-FCPrimary sensor, one per row
9MINI-S-PP-FC-IP20Secondary sensors in the rest of the row
3PP-DIM-J-120-277VDimming power pack, one per row

Tech sheet: ES-TS-101 / 102

C

Solution C: Networked fixture modules

INGY mesh · for networked projects
  • Fixture with sensor module
  • Wireless mesh link

When the building runs a networked system, INGY MOD17M modules build sensing into each fixture and share it across the network for grouping, scenes and reporting.

  • Same MOD17M format as the stand-alone module
  • Grouping and settings are done in the network's set-up tool
  • Specify at fixture order for factory install
QtyModelDescription
12INGY-MOD17M10V12VINGY luminaire sensor module, 0-10V
1212 V DC supplyPer DANLERS wiring guide

Tech sheet: ES-TS-202

Design tips

Related tech sheets

ES-TS-104 ISI smart sensors · ES-TS-101 MINI ceiling & fixture sensors · ES-TS-102 Power packs · ES-TS-202 INGY modules & thermal sensor

Download this guide as a PDF. Other guides: Private offices · Open offices & classrooms · Warehouses & high bay · Restrooms & stalled spaces · Hotels & dorms

Starting points only: check every project against its adopted energy code, the reflected ceiling plan and current manufacturer data. Diagrams are illustrative. Send plans to info@energiocontrols.com for a project layout. Products by B.E.G., DANLERS and ILLUMRA. Photo: Unsplash License.